Attachment Burbank-OET65-DL2007

This document pretains to SES-LIC-20070802-01023 for License on a Satellite Earth Station filing.

IBFS_SESLIC2007080201023_580820

FCC OET-65 RF Exposure Study - Satellite Uplink Facility
NBC Burbank 3.7 meter Digital Ku-band uplink

FCC Maximum Permissible Exposure Levels                   Source                    Units
Public/uncontrolled area exposure limit                   47CFR §1.1310           1 mW/cm2
Occupational/controlled area exposure limit               47CFR §1.1310           5 mW/cm2

Input Data
Antenna Diameter                                          datasheet            370.0 cm
Antenna surface area                                      calculated        107521 cm2
Sub-reflector diameter                                    measured           48.260 cm
Sub-reflector area                                        calculated           1829 cm2
Feed flange diameter                                      measured           17.145 cm2
Feed flange area                                          calculated             231
Frequency                                                 (entry)             14500 MHz
Wavelength (speed of light = 299,792,458 m/s)             calculated          2.068 cm
Transmit power at flange                                  Application       200000 milliwatts
Antenna gain                                              datasheet             52.9 dBi
Antenna gain factor                                       calculated        194984
Height of base of antenna above ground                    measured               2.3 m
Height of center of antenna above ground                  measured               4.3 m
Minimum Elevation Angle                                   (entry)                 32 degrees
Minimum Elevation Angle                                   calculated        0.55851 radians
                                                                                                FCC Maximum Permissible Exposure (MPE)
Results calculated using FCC Bulletin OET-65 (Edition 97-01 August 1997)                          Uncontrolled            Controlled
Maximum power density at antenna surface              Eq. 11 Pg 27           7.44 mW/cm2        Potential Hazard       Potential Hazard
Power density at subreflector                         Eq. 11 Pg 27         437.35 mW/cm2        Potential Hazard       Potential Hazard
Power density at feed flange                          Eq. 11 Pg 27        3465.17 mW/cm2        Potential Hazard       Potential Hazard
Extent of near-field                                  Eq. 12 Pg 27          16554 cm
Maximum near-field power density                      Eq. 13 Pg 28            4.59 mW/cm2       Potential Hazard             Below FCC MPE
Aperture efficiency                                   Eq. 14 Pg 28            0.62
Distance to beginning of far-field                    Eq. 16 Pg 29       39728.48 cm
Power density at end of the transition regiion        Eq. 17 Pg 29           1.91 mW/cm2        Potential Hazard             Below FCC MPE
Maximum far-field power density                       Eq. 18 Pg 29          1.966 mW/cm2        Potential Hazard             Below FCC MPE

Main Beam Far-field region safe exposure distances
Minimum distance for public/uncontrolled exposure         Eq. 18 Pg 29       557.07 meters
   Height at minimum antenna elevation angle              calculated          299.5 meters
   Horizontal distance                                    calculated         472.42 meters

Minimum distance for occupational/controlled exposure     Eq. 18 Pg 29       249.13 meters
   Height at minimum antenna elevation angle              calculated         136.32 meters
   Horizontal distance                                    calculated         211.27 meters

Off-Axis Near Field/Transition Region safe exposure distances from antenna
(20 dB reduction in power density at distances greater
than one antenna diameter from the main beam center.) OET-65 Pg 30
Maximum off-axis near field power density              Eq. 13 Pg 28        0.0459 mW/cm2        Below FCC MPE                Below FCC MPE
Public/uncontrolled exposure off-axis distance         Diam/or Eq 17          3.7 meters
Occupatonal/controlled exposure off-axis distance      Diam/or Eq 17          3.7 meters

Off-Axis Far Field safe exposure distances from the antenna
(Based on side lobe attenuation required by FCC 25.209(a)(2))
Angle off main beam axis (1 to 48 degrees)                (entry)                 1 degree(s)
     Off-axis antenna gain factor                         OET-65 Pg 30*       1585
     Minimum distance for public/uncontrolled exposure    Eq. 18 Pg 29 **    397.28 meters
 * Gain converted from dBi to linear multiple
 ** If calculated distance is less than the start of the
   far field region, the distance to the start of the far
   field region is used.
                                                                                                  Prepared by Doug Lung, NBC Universal, July 27, 2007



Document Created: 2007-07-27 17:08:21